Stop Setup
Explanation
This activity is used to stop a started setup on one or several operations.
This activity contains a Security Checkpoint which can be activated by an
administrator. With an activated security checkpoint on a function you will have
to authenticate yourself again in order to fulfill the function. Additionally,
whenever a security checkpoint is successfully passed a security checkpoint log
is written, creating an audit trail of what is done.
Prerequisites
The setup must have been started on the operation.
System Effects
- The started setup will be stopped for the selected operation and all
operations with the same clocking sequence.
- The stop time will be recorded on the clockings. The clockings can be
viewed in the Clockings tab.
- The monkey wrench symbol the operation had during the setup will be now
removed.
- If Stop Reason is set to Interrupted an exclamation mark
will appear to the left in the operation list.
- The status of the operation will be set with regards to the value
selected in Stop Reason and previous reports:
- Setup Started - When no runtime or quantity is
reported on the operation and Stop Reason is set to Setup Partly
Reported.
- Setup Complete - When no runtime or quantity is
reported on the operation and Stop Reason is set to Setup
Completed.
- Interruption - When Stop Reason has been set
to Interrupted.
- Partly Reported - When a runtime and or quantity
has been reported on the operation.
- Transactions are created in operations history:
The total time is calculated and one transaction per clocking and operation
is created in operation history.
Time is calculated as: Stop time – Start time; calendar
consideration
For Machine Time the work center calendar is used.
For Labor Time the labor class calendar is used. If the employee has
a calendar connected this will override the labor class calendar for the
labor time.
Depending on the site settings either all time, only calendar time or
calendar and overtime is included.
In Anonymous Reporting mode, the crew size defined in the start
dialog box will be saved on the labor transaction and used in the cost
calculation.
In Employee Reporting mode, one transaction per employee is created and
the crew size is calculated with regards to other overlapping clockings for
the employee.
The total time on the operations started at the same time (with the same
clocking sequence) will be proportionally divided among the operations
according to the planned time defined on the shop order operation line.
Example: three operations have 10, 15, and 22 planned minutes (planned total
of 47 minutes), and in total 62 actual minutes are reported.
10/47x62=13,1915
15/47x62=19,7872
22/47x62=29,0213
13,1915 + 19,7872 + 29,0213 = 62
Window
Shop Floor Workbench
Time Clock
Related Window Descriptions
Shop Floor Workbench
Stop Setup
Approve Operation
Time Clock
Procedure
To perform this activity from Shop Floor Workbench using
Stop Setup:
- In the Shop Floor Workbench window, select
the operation and click Stop Setup.
- The
Stop Setup dialog box will
open.
- Select an appropriate option in the Stop Reason list.
- Click OK. The finish time can be viewed in the Clockings
tab.
To perform this activity from Shop Floor Workbench using
Approve Operation:
- In the Shop Floor Workbench window, select
the operation line and click Approve Operation.
- The Approve Operation dialog box will open.
- Select the Stop Clockings check box.
- Click OK. The finish time can be viewed in the Clockings
tab.
To perform this activity from Time Clock:
- Click the Stop Setup button in Time
Clock.
- Enter the Employee ID or the Team.
- Operation IDs with ongoing setup by the employee
or the team will be listed, select the operation ID you want to stop setup
for.
- If you want to stop the machine setup clocking
also, select Yes in Machine Time.
- If you want to report an interruption, select an
interruption cause. Otherwise leave the field empty.
- If you want to close the operation select Yes
in Close Operation.
- Click Ok.